1. the main features
▲ Interference with the new hardware and software design have strong interference
rejection capability, to meet international standards (IEC61000) index requirements.
▲ adjusted using the I2C and storage technology, data protection save power.
▲ first designed for the user "analog output state detection" function, ergonomic design
greatly facilitate the users to install before the temperature controller testing and
debugging.
▲ fan motivation (regular start and stop) feature, to avoid long periods of time to run
the fan locked rotor corrosion.
▲ with 4 ~ 20mA analog current output. With RS-485 asynchronous communication.
2.The Introduction of the Model and Function
Model
|
Function
|
D
(routine)
|
Three-phase circular display /maximum value display and exchange; Input circuit open alarm display and output; Self-check fault alarm display and output; Over-temperature alarm display and output; Over temperature trip display and output; Fan automatic control method/hand control method and exchange; Digital compensation of three phase display value; Time start and stop control of the fan; Output control function test ; “Black box” function
|
E
|
Including all the D functions, besides, the function of three independent current output 4~20mA is additional.
|
F
|
Including all the D functions, besides, the function of series communication of RS-485 is additional.
|
G
|
Including all the D functions, besides, the function of environment temperature measure, display and control is additional.
|
I
|
Including all the D functions, besides, the function of transformer core temperature measure, display and control is additional.
|
NOTE:The idiographic type please make reference to the manufacture outline photo and corresponding type of the back cover, D、E、F、G、I type is carved up from idiographic function, and belongs to function character. Otherwise, it appears the finally bit in the type commonly.
3. technical indicators
1, measurement range: 0.0 ~ 200.0 ℃
2, measurement accuracy: ± 1% FS (Temperature Controller 0.5, sensor 0.5)
3, resolution: 0.1 ℃
4, the digital compensation range: -19.9 ℃ ~ +19.9 ℃
5, using the conditions: ambient temperature -20 ~ +55 ℃
Relative humidity <85%
Supply voltage 220V (+10%, -15%)
Power frequency (50HZ ~ 60HZ) ± 2HZ
6, relay contact outputs: fan contact capacity: 7A/250VAC; 7A/30VDC
Control output capacity: 7A/250VAC; 7A/30VDC
7, temperature controller power consumption: ≤ 8W
8, temperature control instrument Weight: about 1kg
9, Overall Dimensions: 80mm × 160mm × 140mm (H × W × D)
10, hole size: 76 +1 mm × 152 +1 mm (width × height)
11, sensor type: Pt100 (φ4 × 40mm)
12, analog current output: 4 ~ 20mA (linear corresponding to 0.0 ~ 200.0 ℃), the load
resistance ≤ 500Ω
13, Communication: RS-485 communication is connected with RS-485/232 Interface, up to 28 sets of temperature controller connected, communication range up to 1200 meters
14, production standards: JB/T7631-2005 "transformer resistance thermometer"
15, through the certification standards: ISO9001 international quality management system
certification
16, by the test standards: IEC61000-4: 1995 International Standard GB/T17626-1998
"EMC test and measurement technology" standards
17 pilot projects by the anti-jamming
1) The common-mode AC 250V (50HZ) or series mode AC 200mV (50HZ) interference
voltage, the display changes less than the basic error.
2) Electrical Fast Transient: temperature controller power cord and input / output
terminal can withstand the frequency 5KHz, voltages were 1KV 2KV and electrical
fast transient test, display and control the absolute value of additional error limits to
meet the standards .
3) Static Interference: the temperature control unit can withstand electrostatic discharge
test 8KV, display and control the absolute value of additional error limits to meet the
standards.
4) Space radio frequency interference: the temperature control unit can withstand a
frequency of 80 ~ 1000MHz, field strength 10V / m electromagnetic field radiation
tests, the display and control the absolute value of additional error limits to meet the
standards.