1. the main features ▲ Interference with the new hardware and software design have strong interference rejection capability, to meet international standards (IEC61000) index requirements. ▲ adjusted using the I2C and storage technology, data protection save power. ▲ first designed for the user "analog output state detection" function, ergonomic design greatly facilitate the users to install before the temperature controller testing and debugging. ▲ fan motivation (regular start and stop) feature, to avoid long periods of time to run the fan locked rotor corrosion. ▲ with 4 ~ 20mA analog current output. With RS-485 asynchronous communication.
2. technical indicators 1, measurement range: 0.0 ~ 200.0 ℃ 2, measurement accuracy: ± 1% FS (Temperature Controller 0.5, sensor 0.5) 3, resolution: 0.1 ℃ 4, the digital compensation range: -19.9 ℃ ~ +19.9 ℃ 5, using the conditions: ambient temperature -20 ~ +55 ℃ Relative humidity <85% Supply voltage 220V (+10%, -15%) Power frequency (50HZ ~ 60HZ) ± 2HZ 6, relay contact outputs: fan contact capacity: 7A/250VAC; 7A/30VDC Control output capacity: 7A/250VAC; 7A/30VDC 7, temperature controller power consumption: ≤ 8W 8, temperature control instrument Weight: about 1kg 9, Overall Dimensions: 80mm × 160mm × 140mm (H × W × D) 10, hole size: 76 +1 mm × 152 +1 mm (width × height) 11, sensor type: Pt100 (φ4 × 40mm) 12, analog current output: 4 ~ 20mA (linear corresponding to 0.0 ~ 200.0 ℃), the load resistance ≤ 500Ω 13, Communication: RS-485 communication is connected with RS-485/232 Interface, up to 28 sets of temperature controller connected, communication range up to 1200 meters 14, production standards: JB/T7631-2005 "transformer resistance thermometer" 15, through the certification standards: ISO9001 international quality management system certification 16, by the test standards: IEC61000-4: 1995 International Standard GB/T17626-1998 "EMC test and measurement technology" standards 17 pilot projects by the anti-jamming 1) The common-mode AC 250V (50HZ) or series mode AC 200mV (50HZ) interference voltage, the display changes less than the basic error. 2) Electrical Fast Transient: temperature controller power cord and input / output terminal can withstand the frequency 5KHz, voltages were 1KV 2KV and electrical fast transient test, display and control the absolute value of additional error limits to meet the standards . 3) Static Interference: the temperature control unit can withstand electrostatic discharge test 8KV, display and control the absolute value of additional error limits to meet the standards. 4) Space radio frequency interference: the temperature control unit can withstand a frequency of 80 ~ 1000MHz, field strength 10V / m electromagnetic field radiation tests, the display and control the absolute value of additional error limits to meet the standards.
3.Model Example LD-B10-10D LD-B10-10E LD-B10-10EF LD-B10-10F LD-B10-10DP LD-B10-10EI LD-B10-10EFI LD-B10-10FI LD-B10-10DJ LD-B10-10EG LD-B10-10EFG LD-B10-10FG LD-B10-10G LD-B10-10EP LD-B10-10EFP LD-B10-10FP LD-B10-10DP(B) LD-B10-10DCP(B) LD-B10-10GP(B) LD-B10-10IP(B) LD-B10-10EP(B) LD-B10-10EIP(B) LD-B10-10EGP(B) LD-B10-10ECP(B) LD-B10-10FP(B) LD-B10-10FIP(B) LD-B10-10FGP(B) LD-B10-10FCP(B) LD-B10-10EFP(B) LD-B10-10EFIP(B) LD-B10-10EFGP(B) LD-B10-10EFCP(B)
The above models are some examples. If there are special requirements. Explain before ordering.
|
|