1. the main features ▲ linear high platinum resistor winding temperature monitoring, and high reliability. ▲ liquid crystal display and LED indicator lights, work status, and measurements show more intuitive. ▲ the calendar clock, no need to re-set the clock after power outages. ▲ a standard RS-485 or PROFIBUS-DP communication interface. ▲ using new anti-jamming design to meet the national standard indicators of the electromagnetic compatibility requirements. 2. the technical parameters
1, measurement range: 0.0 ~ 200.0 ℃ 2, measurement accuracy: ± 1% FS (0.5 thermostat, sensor 0.5) 3, resolution: 0.1 ℃ 4, the digital compensation range: -19.9 ℃ ~ +19.9 ℃ 5, temperature sensor type: Pt100 6, relay contact output: Fan control contact capacity: 7A/250VAC Alarm control output capacity: 7A/250VAC; 5A/220VDC 7, analog signal output: 4 ~ 20mA four 8, means of communication: RS-485 or PROFIBUS-DP bus 9, protection rating: not less than IP54 10, using the conditions: ambient temperature -20 ~ +55 ℃ Relative humidity <90% (25 ℃) Supply voltage 220V (+10%, -15%) Power frequency (50HZ ~ 60HZ) ± 2HZ 11 Installation: Wall 12, production standards: JB/T7631-2005 "transformer resistance thermometer" and IEC61000-4: 1995 International Standard GB/T17626-1998 "EMC test and measurement technology" standards 13, the product quality system: ISO9001 international quality management system certification 14, through the interference of pilot projects: 1) The common-mode AC 250V (50HZ) or series mode AC 200mV (50HZ) interference voltage, the display changes less than the basic error. 2) Electrical fast transients: thermostat power cord and input / output terminal can withstand the frequency 5KHz, voltages were 1KV 2KV and electrical fast transient test, display and control the absolute value of additional error limits to meet the standards . 3) Static Interference: 8KV thermostat can withstand electrostatic discharge test, display and control the absolute value of additional error limits to meet the standards. 4) Space radio frequency interference: thermostat can withstand the frequency of 80 ~ 1000MHz, field strength 10V / m electromagnetic field radiation tests, the display and control the absolute value of additional error limits to meet the standards. 3.Model Example LD-BK10-220YF LD-BK10-220YFC LD-BK10-220YFL LD-BK10-220YFLC LD-BK10-220YFG LD-BK10-220YFGLC LD-BK10-220YEF LD-BK10-220YEFI LD-BK10-220YEFG LD-BK10-220YEFC LD-BK10-220YEFIC LD-BK10-220YEFGLC LD-BK10-220YEFL LD-BK10-220YEFIL LD-BK10-220YEILC LD-BK10-220YEFGI LD-BK10-220YEFGIC LD-BK10-220YEFGILC
The above models are some examples. If there are special requirements. Explain before ordering.
|
|