LD-B10-T220emperature control of series dry-type transformer

Model No.︰LD-B10-T220EFTH
Brand Name︰LD
Country of Origin︰China
Share on:

 Total 10 Related Items 
12345Next

Product Description

1. the main features

Interference with the new hardware and software design have strong interference      

rejection capability, to meet international standards (IEC61000) index requirements.
   ▲ adjusted using the I2C and storage technology, data protection save power.
   ▲ first designed for the user "analog output state detection" function, ergonomic design  

     greatly facilitate the users to install before the temperature controller testing and  

     debugging.
   ▲ fan motivation (regular start and stop) feature, to avoid long periods of time to run  

     the fan locked rotor corrosion.
   ▲ with 4 ~ 20mA analog current output. With RS-485 asynchronous communication.

2The Introduction of the Model and Function

Model

Function

 

 

 

 

D

(routine)

Three-phase circular display /maximum value display and exchange; Input circuit open alarm display and output; Self-check fault alarm display and output; Over-temperature alarm display and output; Over temperature trip display and output; Fan automatic control method/hand control method and exchange; Digital compensation of three phase display value; Time start and stop control of the fan; Output control function test ; “Black box” function

E

Including all the D functions, besides, the function of three independent current output 4~20mA is additional.

F

Including all the D functions, besides, the function of series communication of RS-485 is additional.

G

Including all the D functions, besides, the function of   environment temperature measure, display and control is additional.

I

Including all the D functions, besides, the function of transformer core temperature measure, display and control is additional.

  NOTEThe idiographic type please make reference to the manufacture outline photo and corresponding type of the back cover,  DEFGI type is carved up from idiographic function, and belongs to function character. Otherwise, it appears the finally bit in the type commonly.

 


3. technical indicators

1, measurement range: 0.0 ~ 200.0
2, measurement accuracy: ± 1% FS (Temperature Controller 0.5, sensor 0.5)
3, resolution: 0.1
4, the digital compensation range: -19.9 ~ +19.9
5, using the conditions: ambient temperature -20 ~ +55
                           Relative humidity <85%
                           Supply voltage 220V (+10%, -15%)
                           Power frequency (50HZ ~ 60HZ) ± 2HZ
6, relay contact outputs: fan contact capacity: 7A/250VAC; 7A/30VDC
                                       Control output capacity: 7A/250VAC; 7A/30VDC
7, temperature controller power consumption: ≤ 8W
8, temperature control instrument Weight: about 1kg
9, Overall Dimensions: 80mm × 160mm × 140mm (H × W × D)
10, hole size: 76 +1 mm × 152 +1 mm (width × height)
11, sensor type: Pt100 (φ4 × 40mm)
12, analog current output: 4 ~ 20mA (linear corresponding to 0.0 ~ 200.0 ), the load  

   resistance ≤ 500Ω
13, Communication: RS-485 communication is connected with RS-485/232 Interface, up to 28 sets of temperature controller connected, communication range up to 1200 meters
14, production standards: JB/T7631-2005 "transformer resistance thermometer"
15, through the certification standards: ISO9001 international quality management system

   certification
16, by the test standards: IEC61000-4: 1995 International Standard   GB/T17626-1998

   "EMC test and measurement technology" standards

17 pilot projects by the anti-jamming
      1) The common-mode AC 250V (50HZ) or series mode AC 200mV (50HZ) interference

     voltage, the display changes less than the basic error.
      2) Electrical Fast Transient: temperature controller power cord and input / output

     terminal can withstand the frequency 5KHz, voltages were 1KV 2KV and electrical    

     fast transient test, display and control the absolute value of additional error limits to

     meet the standards .
      3) Static Interference: the temperature control unit can withstand electrostatic discharge

     test 8KV, display and control the absolute value of additional error limits to meet the

     standards.
      4) Space radio frequency interference: the temperature control unit can withstand a

     frequency of 80 ~ 1000MHz, field strength 10V / m electromagnetic field radiation   

     tests, the display and control the absolute value of additional error limits to meet the

     standards.

Product Image


Related Products
LD-B10-10emperature control of series dry-type transformer
LD-B10-10emperature control of series dry-type transformer
BWDK-3206H
BWDK-3206H
BWDK-3206A
BWDK-3206A
BWD Temperature control of series dry-type transformer
BWD Temperature control of series dry-type transformer

Home  |  Product Center  |  News  |  Contact Us  |  Documents  |  Sitemap  |  Mobile Version
  简体版     繁體版     English
Powered by DIYTrade.com
HomeContact UsSitemap